北京旌派干式血液溶漿機(jī)產(chǎn)品說明:
Jipad品牌Jipad-6GL干式血液溶漿機(jī)利用隔水膜袋“隔水解凍”,完全實(shí)現(xiàn)了血漿干式解凍的目的,解凍結(jié)束:“血漿外觀干燥,透明、無水漬,污物,標(biāo)簽不會(huì)模糊、脫落”。特制熱交換系統(tǒng)能夠達(dá)到“快速解凍”的效果。專門設(shè)計(jì)的“搖勻系統(tǒng)”避免血漿內(nèi)纖維蛋白凝結(jié)。“返回水設(shè)計(jì)”有利融化箱內(nèi)水溫恒定無熱點(diǎn)。
Jipad-6GL干式血液溶漿機(jī)結(jié)構(gòu)合理,緊湊,零部件經(jīng)老化等特殊處理,性能穩(wěn)定可靠,整機(jī)使用壽命長(zhǎng),不同型號(hào)的產(chǎn)品適合不同規(guī)模的醫(yī)院輸血科,血庫使用,并經(jīng)多家醫(yī)院臨床驗(yàn)證。
北京旌派干式血液溶漿機(jī)產(chǎn)品特點(diǎn):
1. Jipad-6GL
干式血液溶漿機(jī)采用美國(guó)DS18B20和雙金屬片兩級(jí)溫控系統(tǒng),超溫自動(dòng)報(bào)警并切斷電源。解凍時(shí)間20分鐘±2分鐘。
2.專門設(shè)計(jì)的的“搖擺錘擊”系統(tǒng),避免血漿內(nèi)纖維蛋白析出。“隔水膜袋”用醫(yī)用綠色新型材料制成,無毒,無味,無毒副作用、使用壽命長(zhǎng)。
3.水箱密封,長(zhǎng)期不用換水,加入專用消毒劑(氯片)效果更好,節(jié)約資源減輕換水負(fù)擔(dān)。儀器對(duì)環(huán)境不會(huì)有水漬、污物溢出,保護(hù)環(huán)境和操作人員。
4.如有血漿袋破裂因有隔水膜袋包裹,不會(huì)造成過量滲漏,污染水箱及環(huán)境.
北京旌派干式血液溶漿機(jī)技術(shù)參數(shù):
1.電源電壓:220V/50HZ
2.功率:1800W
3.可調(diào)溫度:30℃---41℃<±1℃
4.解凍袋數(shù):1-6袋(50-200毫升血漿)
5.解凍時(shí)間:10-20min±2min
6.容量:*多12袋(200毫升血漿)
7.可調(diào)時(shí)間:1min--99.00min
8.儀器重量:29kg加水:45kg
9.外形尺寸:460X610X960(mm)
10.搖擺頻率:50次/分鐘
11.循環(huán)能力:40L
北京旌派干式血液溶漿機(jī)裝 機(jī) 方 法:
1、將壓水棒放入隔水膜袋中
2、打開儀器上面小蓋、加入干凈的自來水,*好是純凈水。(儀器可長(zhǎng)期不用換水。使用一段時(shí)間后,在儀器工作時(shí),提起隔水膜袋觀察水的清澈程度確定是否需要換水)
3、加水時(shí)請(qǐng)注意觀察蜂鳴報(bào)警聲停止,停止說明水位已加滿請(qǐng)停止加水,過多加水,儀器左側(cè)溢水口,會(huì)有水溢出。
4、加水過多時(shí)側(cè)面會(huì)有水溢出,這樣不會(huì)影響儀器使用,您可在側(cè)面放水閥門放出少許即可。
5、等待40-50分鐘顯示屏實(shí)際溫度顯示37度,即可將血漿放入隔水膜袋中點(diǎn)擊“開/關(guān)”按鈕-------OK。
6、如需要改變?cè)O(shè)定溫度、時(shí)間請(qǐng)參照操作手冊(cè)。
目的
建立循環(huán)水浴箱解凍新鮮冰凍血漿、普通冰凍血漿及冷沉淀標(biāo)準(zhǔn)操作規(guī)程,規(guī)范冰凍血液成分解凍操作流程,確保血液質(zhì)量安全。
職責(zé)
本科室工作人員應(yīng)用此操作規(guī)程,保證為臨床提供安全的血漿。
原理
冰凍血漿融化箱采用電氣控制原理,新鮮冰凍血漿、普通冰凍血漿及冷沉淀等需要在 37 一 40℃穩(wěn)定溫度條件下,快速解凍防止蛋白成分析出 ,循環(huán)水溶箱可以維持穩(wěn)定溫度的水 浴條件,快速、批量觧凍,冰凍血液制品,確保觧凍速度和血液質(zhì)量。
適用范圍
適用于循環(huán)水浴箱解凍新鮮冰凍血漿、普通冰凍血漿及冷沉淀操作。
器材與試劑
1、器材:血庫專用融漿機(jī),血漿解凍袋
環(huán)境條件 溫度:20-27℃,溫度≤80% 七、操作程序:
1、連接進(jìn)水管,排水管,接通電源;
2、打開電源開關(guān),按“啟動(dòng)"鍵,提示“缺水"狀態(tài),擰開水龍頭開始加水,直至進(jìn)水完成,“預(yù)溫"燈亮;
3、設(shè)定解凍濕度(一般設(shè)定為38℃)及解凍時(shí)間(根據(jù)解凍血漿數(shù)量確定,一般設(shè)定在16分鐘以上);
4、待預(yù)溫完成后,水箱水位上升到工作狀態(tài);
5、將血漿或冷沉淀從低溫冰箱中取出,去掉包裝盒,套上解凍袋,放入解凍槽中,蓋好解凍箱蓋;
6、解凍完成后,依次將血漿解凍袋取出,將血漿去掉解凍袋后放置室溫下待用;
7、如果解凍后的血漿溫度己經(jīng)恢復(fù)到室溫仍未發(fā)出,應(yīng)該將血漿轉(zhuǎn)移到4℃儲(chǔ)血冰箱內(nèi)待用。
北京旌派干式血液溶漿機(jī)注意事項(xiàng)
1、解凍箱應(yīng)使用獨(dú)立的三芯插座;
2、解凍箱上水時(shí)務(wù)必連好排水管,防止加水過量后溢水; 3、發(fā)現(xiàn)有破損血漿時(shí)需立即換水,并進(jìn)行清洗
4、要避免血袋標(biāo)簽等物品落入水箱內(nèi),以免堵塞水管,致使水循環(huán)系統(tǒng)癱瘓;
5、解凍箱長(zhǎng)期不用時(shí),應(yīng)將解凍箱內(nèi)的水全部排盡。
保養(yǎng)與維護(hù)
1、解凍箱應(yīng)每周做清洗保養(yǎng)一次,清洗內(nèi)外表面;
2、溫度校正:每年由計(jì)量部門對(duì)解凍箱進(jìn)行一次溫度檢測(cè),如發(fā)現(xiàn)實(shí)測(cè)溫度與顯示溫度相差0.5℃以上,應(yīng)對(duì)解凍箱進(jìn)行校正
Product Description:
The Jipad brand Jipad-6L dry blood plasmapheresis machine uses the water separating membrane bag to separate the water and thaw. The purpose of plasma dry thawing is completely realized. The end of thawing is: "the appearance of the plasma is dry, transparent, waterless, dirty, and the label will not be fuzzy and falling off". The special heat exchange system can achieve the effect of "fast thawing". The specially designed "shake up system" avoids fibrin condensation in the plasma. The "return water design" is favorable for the constant water temperature in the melting box without hot spot.
The Jipad-6L dry blood dissolving machine has a reasonable and compact structure. The components are treated by aging and other special treatments. The performance is stable and reliable, and the whole machine has long service life. Different types of products are suitable for different scale hospitals transfusion department, blood bank is used, and is verified by many hospitals.
Product features:
The 1. Jipad-6L dry blood plasma dissolve machine adopts the two level temperature control system of American DS18B20 and bimetallic chip, which can alarm automatically and cut off the power. The thawing time was 20 minutes and 2 minutes.
2. specially designed "swing hammer" system to avoid fibrin precipitation in the plasma. "Water diaphragm bag" is made of new medical green materials, which is non-toxic, tasteless, non-toxic side effects and long service life.
3. water tank is sealed for a long time without changing water. The effect of adding special disinfectant (chlorine tablet) is better, saving resources and reducing the burden of water exchange. The instrument does not have water stains, spillage of dirt, protection of the environment and the operator.
4. if the rupture of a plasma bag is wrapped in a membrane bag, it will not cause excessive leakage and pollute the water tank and the environment.
Technical parameters:
1. power supply voltage: 220V/50HZ
2. power: 1800W
3. adjustable temperature: 30 C ---41 C < + 1 c
4. the number of thawing bags: 1-6 bags (50-200 ml plasma)
5. thawing time: 10-20min + 2min
6. capacity: a maximum of 12 bags (200 ml of plasma)
7. adjustable time: 1min--99.00min
8. instrument weight: 29kg adding water: 45kg
9. shape size: 460X610X960 (mm)
10. swing frequency: 50 times / minute
11. cycle ability: 40L
Installation method:
1. Put the water rod in the water - proof bag
2. Open the top of the instrument and add clean tap water. It is best to clean water. (the instrument can not change water for a long time. After working for a period of time, in the work of the instrument, the clarity of water in the water diaphragm bag is raised to determine whether the water is needed for water exchange.
3, when you add water, please observe the stop of the beep alarm, stop indicating that the water level has been filled, stop adding water, add too much water, and the overflow on the left side of the instrument will overflow the water.
4, when the water is overloaded, there will be water overflow, which will not affect the use of the instrument, you can release a little on the side of the water valve.
5, waiting for 40-50 minutes to display the actual temperature of the display 37 degrees, you can put the plasma into the water septum bag and click "open / close" button -------OK.
6, if you need to change the setting temperature and time, please refer to the operation manual.
I. purpose
Establish standard operation procedures for circulating frozen water tank, thawing fresh frozen plasma, ordinary frozen plasma and cold precipitation, and standardize the operation process of frozen blood components, so as to ensure the quality and safety of blood.
Two. Responsibilities
The staff in this department use this procedure to ensure the safety of plasma in the clinic.
Three. Principle
Frozen plasma melting box adopts the principle of electrical control, fresh frozen plasma, ordinary frozen plasma need to be in a stable temperature 37 to 40 DEG C, rapid thawing to prevent protein precipitation, circulating water soluble box can maintain stable temperature of water bath, fast and batch frozen frozen blood products, explanation, to ensure that the explanation of freezing the speed and quality of blood.
Four. Scope of application
It is suitable for the defrosting of fresh frozen plasma, common frozen plasma and cold precipitation.
Five, equipment and reagents
1. Equipment: a special thawing machine for blood bank, a plasma thawing bag
Six, the environmental conditions of temperature: 20-27 degrees, the temperature is less than or equal to 80%, seven operating procedures:
1, connect the inlet pipe, drain pipe, connect the power supply;
2, open the power switch, press "start" key, prompt "water shortage" state, turn off the faucet start adding water, until the water is completed, "pre temperature" light;
3, set the thawing humidity (generally set to 38) and thawing time (according to the number of thawing plasma is determined, generally set at more than 16 minutes);
4. When the temperature is finished, the water level of the water tank rises to the working state.
5. Remove the plasma or cold precipitation from the cryogenic refrigerator, remove the packing box, set the thawing bag, put it in the thawing tank, and cover the thawing box cover.
6. After the defrosting is completed, the plasma thawing bag is taken out in turn, and the plasma is removed after the defrosting bag is placed at room temperature.
7, if the plasma temperature after thawing has not been released to room temperature, the plasma should be transferred to 4 centigrade to be used in the blood storage refrigerator.
Eight. Precautions
1. An independent three core socket should be used in the thawing box.
2, when the thawing box is on the water, be sure to connect the drain pipe to prevent overflowing water. 3, when the damaged plasma is found, water should be changed immediately and cleaned.
4, to avoid the blood bag label and other articles fall into the water tank, so as to avoid blocking the water pipe, causing the water circulation system to be paralyzed.
5. When the thawing box is not used for a long time, all the water in the thawing box should be exhausted.
Nine, maintenance and maintenance
1, the thawing box should be cleaned and maintained once a week, and the inside and outside surface should be cleaned.
2, temperature correction: once a year, the temperature measurement of the thawing box is carried out by the Metrology Department. If we find the difference between the measured temperature and the display temperature is more than 0.5 degrees, we should adjust the thawing box.